About this item

  • TDS Calibration Solution: These standard solutions let you calibrate conductivity instruments to ensure accuracy
  • Proper Application: Use this conductivity calibration solution when readings are expected to be around 1000 µS/cm
  • Reliable Results: All Traceable conductivity and calibration standards are NIST-traceable reference materials; Accredited to ISO 17034 requirements
  • Specs: Average accuracy at 25°C is ±0.25 microsiemens for 1, 5, 10 microsiemen (µS) solutions, or ±0.25% for all other solutions or the tested uncertainty shown on the certificate, whichever is greater; Conductivity options range from 1 to 200,000 µS/cm
  • Cole-Parmer Lab Equipment: Is accurate, dependable, durable, and economical—a practical solution for your laboratory; Designed to meet your everyday requirements and budgetary needs, our products are manufactured in accordance with strict guidelines


These standard solutions let you calibrate conductivity instruments to ensure accuracy. If unopened, shelf life is one year; once opened, shelf life will vary by solution value. Use when readings are expected to be around 1000 µS/cm. Oakton Traceable conductivity and TDS standards have detailed labels: KCl, NaCl, and 442 conversions, temperature corrections, and certified values referenced to 25°C—convenient! Average accuracy at 25°C is ±0.25 microsiemens for 1, 5, 10 microsiemen (µS) solutions, or ±0.25% for all other solutions or the tested uncertainty shown on the certificate, whichever is greater. Conductivity options range from 1 to 200,000 µS/cm. Batch-tested solutions are lot certified; a few bottles from a single lot are analyzed. Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable Conductivity Standards complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, Standard Method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants.


Recommended Products

$143.00

$ 61 .99 $61.99

4.4
Select Option

$35.00

$ 16 .99 $16.99

4.5
Select Option

$88.25

$ 36 .99 $36.99

4.8
Select Option

$13.95

$ 6 .99 $6.99

5.0
Select Option

$29.00

$ 14 .99 $14.99

5.0
Select Option

$107.96

$ 52 .99 $52.99

4.8
Select Option

$44.99

$ 20 .99 $20.99

4.9
Select Option