- Home
-
All Categories
- Sports & Outdoors
- Automotive
- Industrial & Scientific
- Clothing, Shoes & Jewelry
- Musical Instruments
- Kitchen & Dining
- Pet Supplies
- Arts, Crafts & Sewing
- Sports Collectibles
- Baby
- Toys & Games
- Patio, Lawn & Garden
- Computers & Accessories
- Electronics
- Home & Kitchen
- Office Products
- Tools & Home Improvement
- Grocery & Gourmet Food
- Cell Phones & Accessories
- Camera & Photo Products
- Appliances
- Video Games
- Health & Household
- Beauty & Personal Care
- Payment
- About Us
- FAQ
- Privacy Notice
- Shipping & Returns
- Contact Us
Your cart is empty.
Your cart is empty.- Home /
- Industrial & Scientific
- Test, Measure & Inspect
- Fasteners
- Industrial Electrical
- Material Handling Products
- Professional Dental Supplies
- Janitorial & Sanitation Supplies
- Retail Store Fixtures & Equipment
- Power Transmission Products
- Filtration
- Hydraulics, Pneumatics & Plumbing
- Occupational Health & Safety Products
- Food Service Equipment & Supplies
- Cutting Tools
- Lab & Scientific Products
- Additive Manufacturing Products
- Adhesives, Sealants & Lubricants
- Abrasive & Finishing Products
- Raw Materials
- Industrial Hardware
- Commercial Door Products
- Science Education
- Professional Medical Supplies
- Digital Signage
- Packaging & Shipping Supplies
- Robotics
- Power & Hand Tools
/
- Test, Measure & Inspect
- Temperature & Humidity
- Airflow & Air Quality
- Motion, Speed & Force
- Recorders & Data Acquisition
- Substance Analysis Instrumentation
- Electrical Testing
- Dimensional Measurement
- Pressure & Vacuum
- Calibration
- Inspection & Analysis
- Scales & Balances
- Surface & Hardness Testing
- Light Measurement
- Sound & Noise Meters
- Network & Cable Testers
/
- Electrical Testing /
- Power Meters
Product Description
ETCR5000 3 Phase Power Quality Analyzer with ETCR068B φ68mm Current Clamp 1.0A-1000A

Product Functions
- Waveform real-time display (4 channels voltage/4 channels current).
- True RMS values of voltages and currents.
- The DC components of voltages.
- Peak current and voltage values.
- Minimum and maximum half-cycle RMS current and voltage values.
- Phasor diagram display.
- Measurement of each harmonic up to order 50.
- Bar charts show harmonic ratios of current and voltage of each phase.
- Total harmonic distortion (THD).
- Active, reactive, apparent power, by phase and cumulative.
- Active, reactive, apparent energy, by phase and cumulative.
- Transformer K factor.
- Power factors (PF) and displacement factors (DPF or COSΦ).
- Short-term voltage flicker (PST).
- Three phase unbalance (current and voltage).
8 Major Functions

- Test Function: real-time waveform display (4 channels voltage / 4 channels current); voltage and current true RMS; voltage DC component; current and voltage peak; current and voltage maximum/minimum value within a certain time; phasor diagram display; The measurement of each phase harmonics reaches 50 times; the histogram shows the harmonic ratio of each phase current and voltage; the calculation of total harmonic distortion (THD); Active/reactive/apparent power value and total value of each phase; Each phase active/reactive/apparent electrical energy value and total value of each phase; transformer K factor calculation; calculation of COS φ displacement and power factor (PF); flicker calculation; three-phase unbalance calculation ( Voltage and current).
- Capture and Monitoring Functions: Capture detection the instantaneous change of electric network voltage and current parameters, including voltage and current fluctuations, voltage and current swell, sag, short-time interruptions, transient over voltage, impulse current, and current and voltage instantaneous distortion. The instrument can store up to 150 groups of transient waveforms simultaneously.
- Start-up Current Monitoring: It can monitor the inrush current of the circuit and the starting current of the electrical equipment, helpful for the correct design of installed capacity. It can display the rise/fall curve of the effective value in start process, the envelope curve of the start current, 4-channel current and 4-channel voltage waveform. After triggering, can be recorded about 100s, and store all current and voltage instantaneous values and waveform curves in each cycle within 100s.
- Record and Storage Function: All test parameters of basic test functions (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf, Aunb, KF, W, VAR, VA, PF, COSφ, TANφ), voltage 50 times harmonic, current 50 times harmonic, total of 123 parameters for recording, and generate the trend diagram, record data for a long time as required. (Simultaneously select 20 parameters to record once every 5 seconds, can be recorded about 300 days).

- Alarm Function: The limit value of the selected parameters can set according to the require to monitoring whether the parameters exceed the limit,when exceed the limit setting will generate the alarm log , such as voltage overvoltage, current overcurrent, unbalance degree over-limit, certain harmonic ratio over-limit, frequency over-limit, active power over-limit, total harmonic distortion over-limit, etc. At most to set 40 groups of alarm monitoring parameters, each groups can set different monitoring parameters (including 50 times harmonics with 123 different parameters) and the limit value, and set the minimum time of over-limit. Stored Max 12800 groups alarm log.
- Screen capture function: Screen capture can be taken in any test page to store the present screen image, and record time and test mode automatically, Such as saving current voltage waves, harmonic histograms, phasor diagrams, etc. Save up to 60 screenshots simultaneously.
- Communication Function: Through USB communication with the computer, the monitoring software can display the waveform of power quality analysis and test in real time, and can read the detected and captured transient waveform, trend chart record, alarm list, test screenshot, etc.
- Setting Function: The user can set the time and date, the display contrast and brightness, and the corresponding color of each phase line in the instrument; the connection mode and power network type of the instrument can be set; can select different current clamp and different voltage test transformation ratio; Chinese menu or English menu can be selected.
General Specifications
Power Supply | Rechargeable lithium battery pack 9.6V, external battery charger. |
Display Mode | LCD true-color screen, 640 dots×480 dots, 5.6 inch, display area 116mm×88mm. |
Battery Level Indication | The battery symbol 5 cells displays the battery levels. When the battery level is lower, it will shut down automatically after 1 minutes. |
Working Current | About 490mA, The battery works continuously for about 8 hours at full power. |
Current Test | Current Clamp: 008B; 040B; 068B; 300F (optional); Checking following tables for detail parameters. |
Voltage Test | Line Voltage: 1.0V ~ 2000V; Phase Voltage: 1.0V ~ 1000V |
Electricity Energy Parameter | W, VA, Var, PF, DPF, cosφ, tanφ; Wh, Varh, Vah |
Number Of Channels | 4 channels of current and voltage |
Frequency | 40Hz~70Hz |
Harmonic Wave | 0~50 times |
Total Harmonic Distortion | 0~50times, each phase |
Transient Record Groups | 150 groups |
Voltage Flicker | Yes |
Start Current Mode | 100 seconds |
Three-Phase Unbalance | Yes |
Peak Value | Yes |
Phasor Diagram Display | Automatic |
Screenshot Capacity | 60 PCS |
Communication Interface | USB |
Record | 300 days (record 20 parameters at the same time, record 1 parameter every 1 minute). |
Alarm | 40 different types of parameters can be selected, and 12,800 sets of alarm logs. |
SD Memory Card | 2G |
Automatic Shutdown | In the alarm/trend chart recording/transient capture mode (pending or in progress), the instrument will not automatically shut down. In other test mode, no button operation within 15 minutes, automatically shut down after 1 minute prompt. |
Backlight Function | Yes, it is suitable for use in dim place and at night. |
Input Resistance | Test voltage input impedance: 1MΩ |
Suitable Safety Standard | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution Degree 2 |
Withstand Voltage | The sine wave AC voltage of 3700V/50Hz withstand between the instrument circuit and the housing for 1 minute. |
Insulation | The distance between the instrument circuit and the protective case ≥ 10M Ω. |
Meter Size & Weight | 240mmX170mmX68 mm / Host: about 1.6kg (include battery); total weight: about 9.18kg (include package and accessory). |
Working Temperature & Humidity | -10℃~40℃; below 80%RH. |
Store Temperature & Humidity | -10℃~60℃; below 70%RH. |
Accessories | Host: 1PCS; Instrument Bag: 1PCS; Test Cable: 5PCS (yellow, green, red, blue, black); Alligator Clip: 5PCS; Charger 1PCS; Software CD: 1COPY; USB Cable: 1PCS; 2G Memory Card: 1PCS. Current Clamp: (optional) |
Specifications of Current Sensors

If you do not have CD reader in your PC, please feel free to send us message for electronic software.
$115.47 $115.47
$ 49 .99 $49.99
$1,799.00 $1,799.00
$ 99 .00 $99.00
$81.80 $81.80
$ 39 .99 $39.99
$28.58 $28.58
$ 13 .99 $13.99
$26.09 $26.09
$ 12 .99 $12.99
$32.23 $32.23
$ 14 .99 $14.99
$26.00 $26.00
$ 13 .99 $13.99
$39.99 $39.99
$ 20 .99 $20.99