ATO Single Phase VFD for Single Phase Motor 3HP 2.2kW VFD Drive Variable Frequency Drive 220V Single Phase Output VFD Single Phase Motor Speed Controller (1-Phase Input, 1-Phase Output)

Free shipping on orders over $29.99

$378.99

$ 99 .00 $99.00

In Stock
  • 【Parameter】ATO 3HP 2.2KW 19.2A single phase VFD variable frequency drive, single phase 220V input and output vfd, used for single phase AC motor
  • 【Input】input voltage: AC single phase 220V/230V, Input frequency: 47~63Hz
  • 【Output】 Single phase input output VFD output voltage: AC single phase 0~rated input voltage, output frequency: 0~1000Hz
  • 【Control Mode】V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
  • 【Application】ATO single phase ouput VFD drive specialized designed for single phase induction motor, widely applied to control speed of the single phase motors, such as fans, pumps, mixer, extruder, slitter, winder, power tools, etc.
  • 【Customer First】If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h



Product Description

ATO single phase input output vfd
2hp 3hp -single-phase--VFD-details

ATO 1.5kW 2.2kW 220V 230V 240V single phase output VFD inverter is mainly positioned as a high-end market for the specific requirements of fan and pump load applications, its flexible design makes the ATO 1 phase vfd drive can be widely used for speed control accuracy, torque response speed, low-frequency output characteristics and other situations with higher requirements.

ATO 220V 230V 240V single phase input output VFD variable frequency drive is becoming the first choice of more customers.

ATO 220V-240V Single Phase Input Output VFD Common Specification

Capacity 1/2HP/ 1HP/ 2HP/ 3HP/ 5HP/ 7.5HP/ 10HP (optional )
Control mode V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command mode Keypad control, Terminal control, Serial communication control
Frequency setting mode Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Carrier frequency 1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Built-in PID Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulation Torque control without PG
Torque control Keep output voltage constant automatically when input voltage fluctuating
Over load capacity 150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Ambient temperature -10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃)
Humidity 90%RH or less (non-condensing)
Altitude ≤1000M: Output rated power, >1000M: Output derated
Over load capacity 150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
2hp 3hp-vfd-single-phase-input-output

Why Choose ATO Single Phase VFD?

Reduce energy consumption and energy costs

If your application does not need to run at full speed, you can reduce energy costs by using a ATO variable frequency drive vfd to control the motor, which is one of the advantages of a variable frequency drive. VFD allows you to match the speed of electric equipment to load requirements. Using ATO VFD drive can improve product quality and reduce production costs.

Increase production through stricter process control

By running the motor at the most efficient speed for your application, you can reduce the occurrence of errors, thereby increasing the level of production, and thus earning higher revenue for the company.

Extend equipment life and reduce maintenance

When the equipment is controlled by a ATO VFD to ensure the best motor application speed, the service life of the equipment will be longer and downtime will be reduced due to maintenance. Since the VFD can optimally control the frequency and voltage of the motor, the VFD will provide better protection for the motor from electric thermal overload, undervoltage, overvoltage and other problems.

Applications of ATO Variable Frequency Drive:

  • Air conditioner load
  • Crusher load
  • Large furnace calciner furnace load
  • Compressor load
  • Rolling mill load
  • Winding engine load
  • Revolving furnace load
  • Roller load

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.

Shopping guide:

  • The rated current of the motor <the rated current of the vfd
  • The rated power of the motor<the rated power of the vfd

Curtis Eickemeyer
Reviewed in the United States on March 7, 2024
Good instructions on how to set basic parameters. Bad is they don't have live tech support after purchase, only email option, not great when in the field trying to finalize install. I would say if you have a decent amount of experience with vfd and you have a basic application, these drives can definitely save you or customer some money.
Customer
Reviewed in the United States on November 20, 2024
This vfd worked amazing on my delta 28-640. I need to red7ce the rpms the allow speed to buld up. This unit did the trick would purchase another one if I ever come to that situation again.
David C. Damusis
Reviewed in the United States on November 12, 2023
I like the design. Very programmable. Self protecting. Many motor control applications. I used it for single phase slow starting motors.