Your cart is empty.Refrigeration Service Test Kits, Chemicals, and SealersPiercing Valve And Hose, Application Air Conditioning And Refrigeration Systems, For Use With 4050-01, 4050-02, 4050-06, Includes Hose And Valve.
T J
Reviewed in the United States on July 11, 2024
Did the job no leaks quick shipping
Terry Watkins
Reviewed in the United States on July 31, 2023
Well I used calgon can leak sealer for years, wasted many cans trying to get it in , then one day I figured out there is a strader valve where the hose connects to the T handle, so you need to unscrew the blue hose from the T handle and remove the valve and put back together, it works way better that way
ANGEL A.
Reviewed in the United States on June 17, 2023
FIT THE CAN PROPERLY.
todd wild
Reviewed in the United States on January 15, 2020
Worked well for putting sealer in ac system.
Texan2000
Reviewed in the United States on August 24, 2017
This Piercing Valve and Hose worked fine after removing the Schrader valve installed in the hose at the end connected to the piercing valve. Otherwise, there is no way to purge the air after connecting the hose to the low pressure port of the AC System. To remove the valve, you need to disconnect the hose from the Piercing Valve using a 10 mm wrench. Then you will see the Schrader valve in the hose and, with a 4 way tool (it costs less than 2 dollars in Walmart) you are able to remove the Schrader valve. The 4 way tool, is the same used to remove tire valves from cars or bicycles.
David Smith
Reviewed in the United States on July 19, 2015
A good way to put chemicals in your A/C system, but I found done that do what they say.The Fix leak stuff didn't work and now my compressor is shot. Did this cause it? Don't know.It was old to begin with (14 Yrs) so time for a new one anyway.
vidhya srinivas
Reviewed in the United States on May 31, 2015
The product worked great.After connecting the hose to the can and the suction port, Before piercing, I tried to remove moisture/air by loosening the can side but the freon from the system didnt come out. I was worried that the hose has a block and tried unscrewing the hose from the piercing valve. There was another valve to prevent freon to come back to the can. Since the freon is not supposed to come out as per design I was confident and proceed with piercing and added Easy Dry and Easy Seal.
Nik
Reviewed in the United States on May 1, 2015
Used for Easy Seal and Easy Dry. The instructions online say that you need to bleed the line of air by connecting the hose to the AC low pressure side with the canister attached to the other side of the hose then back the canister off a little but this does nothing as the hose has a 1 way valve. This is probably because venting r-22 is illegal. Apart from this one difference in procedure, this hose does what its suppose to.