Your cart is empty.Ignitor Ru80/98 I/E Kb, W/ Ht. This is a genuine OEM (Original Equipment Manufacturer) part.
TD
Reviewed in the United States on July 15, 2024
Parts fit .fast delivery,highly recommend.
VA
Reviewed in the United States on November 18, 2024
Got an Error 11 on Rinnai RL94E tankless water heater. Flame Rod cleaning and replacement did not resolve. No spark was provided by the ignitor wire. This is an almost direct replacement of the original ignitor coil. The wire length on RL94 unit was longer. It was easy to remedy by cutting off the original wire, pulling off the new wire and inserting original into the coil. Hot water is back.Item description is lacking, picture looks identical, except the shorter igniter wire.Replacing a coil is easy - less than 15 minutes if you know what you are doing.Slide off plastic trims on each side of the unit. Remove 4 bolts and pull of the cover. Ignitor wire is right in middle and the coil is in a metal enclosure on the lower right.