1.Size:H150


  • [QUALITY MATERIAL]: Our universal furnace ignitor is composed of 1.97" heating element nitride, 1.18" ceramic insulator body, non glazed, aluminum polished finish, 304 stainless steel bright finish bracket, 15"-3/4 20AWG/ UL 10362 specification 250 degrees Celsius temperature-resistance cable. This universal gas furnace igniter has a large ignition area for better and more lasting ignition
  • [WIDE APPLICATION]: This H150 universal silicon nitride ignitor can replace silicon carbide igniters of gas-fired forced-air furnace and water heater boiler. The universal ignitor can replace more than 150 different igniters, fit for 90% of all applications in the market, such as furnace, warm air movement, gas ignition, infrared light source, pool heater, boilers, cook top and range etc
  • [POWER RATING]: Power: 150 W. Cold resistance : 9-17 Ω. Rated voltage: 120V + 10%-15%, 50/60HZ. Temperature at 120v ± 0.5v. 60HZ at 17 sec ≧1180 ℃. You can measure whether the hot surface ignitor is working properly with a multimeter. Your multimeter should read anywhere from 9 to17 Ohms if the ignitor has continuity. The nitride furnace ignitor should be replaced if there is no reading on the multimeter or very little change
  • [RPOBLEM FIXING]:Our gas furnace ignitor replacement will be needed if furnace will not ignite, ignitor does not glow, crack, burn out, break, moisten, etc
  • [EASY TO INSTALL]: It is easy-peasy to install this 120v universal silicon nitride hot rod ignitor. The mounting bracket for the Ignitors is universal, eliminating the need for multiple brackets. No other special tools are required



Product Description

furnace hot surface igniter
furnace hot surface igniter
furnace hot surface igniter
furnace hot surface igniter
furnace hot surface igniter

Compatible Brands & Model

  • Fit for Carrier/Bryant/Payne F767A-357, F767A-361, LH337C002, LH33Z5001, LH8325001A, LH33Z5002, LH3325002A, LH3325003, LH33Z5003A, LH3325004
  • Fit for COLEMAN/EVCON 025-32625-000, 1474-051, 1474-052
  • Fit for Goodman/Amana 0230K00001, 10735003A, 20165702, 20165703, 201657-03, 201657035, 601, B1401009, B1401015S, B1401018, B14010185, B1401095
  • Fit for Lennox 91X2201, X928101
  • Fit for MOR-FLO 3200580, 3200618, 3210401
  • Fit for Nordyne105141000, 632-0770, 632-0880, 902661A, 903110A, 903758
  • Fit for NORTON 201, 201D, 201J, 201K, 201M, 201N, 201R, 201W, 201Y, 271, 271M, 271N, 271NM, 271P, 271W, 271Y
  • Fit for RAYPAK 600915
  • Fit for Rheem/Ruud 62-22441-01, 62-2286012, 62-22868-82, 62.22868-93
  • Fit for White-Rodgers 21D64-1, 21D64-2, 767A-301, 767A-303, 767A-306, 767A-310, 767A-311, 767A-350, 767A-353, 767A-354, 767A-357, 767A-361, 767-364, 767A-365 , 767A-366, 767A-370, 76A-371, 767A-372,

  • Fit for White-Rodgers 21D64-1, 21D64-2, 767A-301, 767A-303, 767A-306, 767A-310, 767A-311, 767A-350, 767A-353, 767A-354, 767A-357, 767A-361, 767-364, 767A-365 , 767A-366, 767A-370, 76A-371, 767A-372, 767A-373, 767A-374, 767A-376, 767A-377, 767A-378, 767A-382, 767A-383, 767A-384
  • NOTE: This is universal furnace igniter, which can replace more than 150 different igniters, fit for 90% of all applications in the market, such as furnace, warm air movement, gas ignition, infrared light source, pool heater, boilers, cook top and range etc.

Customer
Reviewed in the United States on January 8, 2025
Bought and replaced myself. Worked good until it broke in about 3 months. The wires look at bit charred right behind the white insulation of the unit. Tested for resistance and got 0, so bad unit. I’m going to try a Honeywell universal glowplug, which I hear is better. Buyer beware.
George
Reviewed in Canada on April 19, 2025
Works so far, but I had mistakenly placed the order twice. They arrived in one small package yet I got charged for 2 deliveries.I reported it to Amazon, but got completely ignored. No response!!!
Niroshan Sanmuganathan
Reviewed in Canada on May 14, 2024
Really amazing product. Working great. Thank you so much for selling this kind of universal product.
Customer
Reviewed in the United States on February 27, 2024
OMG…. We tried everything and couldn’t get the heater to turn on then it was really cold. The HVAC company tried to sell us on a new unit but the thing was that it did work, just not when it was too cold. Our unit is in the attic so of course when it was cold outside, the attic would be freezing as well. We tried switching the igniter from the basement unit up to the attic and same problem. We finally decided to try this igniter because it is a longer rod versus a short flat stick.When the product arrived we thought that it would be difficult to install because it’s just cables but it was actually super easy. Instantly it worked! Honestly I was skeptical waiting for a very cold night to see if it would continue to work and it sure did! We got the igniter late November and now almost going into spring, so greatful not to have cold nights!
Grammy
Reviewed in Canada on October 28, 2024
Works just like the original.
Mark
Reviewed in Canada on January 20, 2024
Installed and worked flawlessly.
Kindle Customer
Reviewed in Canada on December 24, 2023
Will take a few years to know how long it lasts. Light shelving plastic package was bent all around in light bubble letter package but no apparent damage. Came though customs quickly enough.Even for a backup it's a must have on hand. 10 minutes and the heat is on again.